Pitting Evaluation on Tank Container
Pitting
Evaluation on Tank Container
Interesting
discussions with some #tankcontainer owners regarding pitting...
ITCO ACC states that corrosion or pitting reducing the shell thickness to less
than the specified minimum or causing contamination, traps are NOT acceptable
conditions and it gives you 3 types (A, B, C)
Type-A Shallow Clean Pit. // Type
B Crater or Pinhole. // Type C – Pore or Cavity;
however, ITCO ACC is a great guideline, very useful and totally applicable but it is not an inspection code
or standard and does not intend to be so... ASTM G46-94 and API 510 ie, will
give better criteria to evaluate a pressure vessel and release it for service
or not... for instance: during the current inspection, widely scattered pits
maybe ignored, for instance when The total area of the pitting that is deeper
than the corrosion, allowance does not exceed 7 in.2 (45 cm2) within any 8-in.
(20- cm).
- Thank you For reading the Small Article on Tank containers.